Blancco WinEraser 10.12.2 has been released!

Blancco WinEraser 10.12.2 has been released!

🧠 Why This Matters (Quick Take) 

  • Network connectivity: BWE must connect to the network for multiple reasons, licensing, report, workflow. Lack of connectivity usually means inability to process a machine. In this sense, this fix release is very important. 

🔧 Stability & Fixes  

Ticket ID 

Category 

Improvement 

Impact 

WD-1279, 

WD-1281, 

WD-1284, 

WD-1288 

Connectivity / Networking 

WinEraser booted successfully but had no network interface. This was due to a Windows update that broke the WinRE image, causing network drivers to fail to bind. 

Important fix for all users: without network, BWE cannot consume licenses or send a report 

WD-1260, 

WD-1280 

Workflow 

IBR (workflow) conditions failed when using the wrong case: lowercase "or", using a different case for "IsValid". This was due to the workflow editor's parsing being case-sensitive; fixed to accept operators in any case. 

Improves the workflows creation and maintenance. 

WD-1277 

Reporting 

Erasure report start/end times were incorrect, causing ServiceNow imports to miss ~25% of reports — fixed by adding a configurable UTC offset applied to timestamps in the XML report. 

Important fix for customers using BWE through a ServiceNow integration. 

WD-1125 

UI/UX 

The "Press any key to boot..." UEFI screen was sometimes missed by the user, which caused failed/delayed boots — that screen is now skipped automatically. 

Usability and automation fix.